VERRAZANO™
INSTALLATION OF WALL CONTROL
Step 6b. The
CAUTION: Ensure power is turned OFF at the breaker or fuse panel before start- ing installation.
1.Remove the screws and switch plate from the existing switch box.
2.Remove the screws holding the switch in the switch box.
3.Pull the existing switch from the switch box to expose the wire connections.
4.Remove the three wires from the switch.
5.Wiring preparation, if required:
Strip wires:
• 3/8” for 14 guage
• 1/2” for 16 and 18 guage
NOTE: The wire connectors provided are suitable for copper wire only. Use to join the following wire combina- tions: One No. 14 gauge with one No. 16 or 18 gauge
6.Connect BLACK lead of control to 120V AC hot wire. Connect the RED lead to the light circuit controlled by slider on right side of unit. Connect YELLOW lead to fan motor(s) wire. The fan speed will be controlled by the left slider on the unit. If unit is used to control only one light circuit, place wire connector on unused lead. Secure these connections with the wire connectors.
7.Install the
CAUTION: Be sure no wires are pinched!
8.Install the wall plate with the two color matched screws.
9.Turn on power to test the controller.
CANOPY HATCH INSTALLATION
Step 7. Tuck the wires into the canopy with the wire nuts pointed upwards, so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires are clear of the canopy opening.
Step 8. Install canopy hatch with the last canopy screw and lock washer. To do this, tilt the fan body away from the hatch opening. Tighten the screws firmly by hand only.
Step 9. Straighten the fan, then check to ensure that there is no movement be- tween the canopy and ceiling or
CANOPY
HATCH
LOCK
WASHER
Note: Write down the Se- rial Number and the model number on the inside front cover of this manualfor future reference.
TILT THE
FAN TO
INSTALL
LAST
CANOPY
SCREW
CANOPY
SCREW
7