Power SCSI termination |
| 10 |
|
Supplies power |
| ON |
|
Does not supply power |
| OFF |
|
Connect the first I/O Box and PC with the SCSI cable.
Then connect the SCSI connector of the I/O Box connected to the PC to the SCSI connector of the other I/O Box via the SCSI cable. Connect the remaining I/O Boxes so that the one with the
terminator setting becomes to the last under
Select a suitable cable that matches the shape of the connector on the PC side to connect the PC and the first I/O Box.
2.3.3 Setup of Satellite I/O Box to Master I/O Box
Note that the DIP switch settings on Master I/O Box and on Satellite I/O Box differ.
DIP switch settings of the Master I/O Box
These settings are the same as stated in Chapter 2.3.2, "Setup of Master I/O Box" except that the no.5 should be set to OFF.
| 1 | 2 | 3 | 4 | 5 |
| 6 | 7 | 8 | 9 | 10 |
| ON | OFF | OFF | OFF | OFF |
| OFF | OFF | OFF | ON | OFF |
DIP switch settings of the Satellite I/O Box |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |
| 1 | 2 | 3 | 4 | 5 |
| 6 | 7 | 8 | 9 | 10 |
| ON | OFF | ON | OFF | OFF |
| OFF | ON | ON | ON | ON |
Set DIP switch no.5 to ON (i.e. setting as a terminator) if the
5
ON
The above setup example assumes that the
setup, refer to Chapter 2.3.1, "Setup of Satellite I/O Box". Connect the first Master I/O Box and PC with SCSI cable.
Then connect the
12