2.3.3 Setup of Satellite I/O Box to Master I/O Box

￿

Power SCSI termination

 

10

 

Supplies power

 

ON

 

Does not supply power

 

OFF

 

Connect the first I/O Box and PC with the SCSI cable.

Then connect the SCSI connector of the I/O Box connected to the PC to the SCSI connector of the other I/O Box via the SCSI cable. Connect the remaining I/O Boxes so that the one with the

￿terminator setting becomes to the last under daisy-chain connection.

Select a suitable cable that matches the shape of the connector on the PC side to connect the PC and the first I/O Box.

2.3.3 Setup of Satellite I/O Box to Master I/O Box

￿Note that the DIP switch settings on Master I/O Box and on Satellite I/O Box differ.

￿

￿

DIP switch settings of the Master I/O Box

These settings are the same as stated in Chapter 2.3.2, "Setup of Master I/O Box" except that the no.5 should be set to OFF.

 

1

2

3

4

5

 

6

7

8

9

10

 

ON

OFF

OFF

OFF

OFF

 

OFF

OFF

OFF

ON

OFF

DIP switch settings of the Satellite I/O Box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

 

6

7

8

9

10

 

ON

OFF

ON

OFF

OFF

 

OFF

ON

ON

ON

ON

Set DIP switch no.5 to ON (i.e. setting as a terminator) if the C-OUT terminal is not connected to another Satellite I/O Box to be daisy-chained.

5

ON

The above setup example assumes that the RS-232C baud rate is 115200 bps. If modifying this

￿setup, refer to Chapter 2.3.1, "Setup of Satellite I/O Box". Connect the first Master I/O Box and PC with SCSI cable.

Then connect the C-OUT terminal of the Master I/O Box connected to the PC to the

C-IN terminal of the other Satellite I/O Box via the RS-422 cable. Connect the remaining I/O Boxes so that the one with the terminator setting becomes the last under daisy-chain connection.

12