Q2
If the Windows3.1 version of FLINK is used, the baud rate setup cannot be modified by changing the DIP switch setting for the
A2
To modify the
Option: /L {baud rate parameter,2,,,,,,, }
9600 for 9600 bps
384K for 38400 bps
115K for 115200 bps
The communication speed can be determined according to the DIP switch setting of the Satellite I/O Box only if the
Q3
If an attempt is made to execute the Upload/Download Utility, a startup error appeared. Why?
A3
This startup error occurs if the COM port is being used by another application.
In addition, if an application that uses the COM port is executed from the DOS window, the COM port is not accessible from other applications until the DOS window has been closed.
Q4
If multiple Satellite I/O Boxes are connected under
A4
This is not permitted. All
Master I/O Box
Q1
If the Master I/O Box is connected, the SCSI check box in LMWIN cannot be selected. Why?
A1
First turn ON the power to the Master I/O Box, then turn ON the power to the PC. If this order is reversed, the I/O Box cannot be recognized by the system. Or, SCSI IDs may be duplicated. Check this.
27