CBM America iDP3240 Specifications of Drawer Kick-Out Connector, Drawer Kick-Out drive signal

Models: iDP3240

1 230
Download 230 pages 48.14 Kb
Page 58
Image 58

8.DRAWER KICK-OUT CONNECTOR AND POWER CONNECTOR

8.1Specifications of Drawer Kick-Out Connector

8.1.1 Drawer Kick-Out drive signal

A pulse specified by ESC p, DLE DC4 is output. In parallel interface mode, the SW(+) state can be confirmed at No. 34 pin of the interface connector or by the DLE EOT, GS a and GS r commands at the serial/parallel interface.

8.1.2 Electrical characteristics

Drive voltage: DC 24 V

Drive current: 0.8 A maximum (Within 510 ms)

• SW signal: Signal level “L” = 0 to 0.5 V “H” = 3 to 5 V

8.1.3 Connector Pin Configuration

No.

Signal

Function

1

FG

Frame Ground

 

 

 

2

DRAWER 1

Drawer 1 drive signal

 

 

 

3

DRSW

Drawer switch input

 

 

 

4

VDR

Drawer drive power supply

5DRAWER 2 Drawer 2 drive signal

6

GND

Common ground on circuits

1 6

Connector used: TM5RJ3-66 (Hirose) or equivalent

Applicable connector: TM3P-66P (Hirose) or equivalent

CAUTION:

No output is produced while printing.

The drawers 1 and 2 cannot be driven simultaneously.

A solenoid used for the drawer should be of 36 Ω or more. The output current should be kept at 0.8 A or less; otherwise, breakdown or burning could occur.

This connector cannot be connected to a telephone line. Do not connect to anything other than the solenoid.

— 39 —

Page 58
Image 58
CBM America iDP3240 manual Specifications of Drawer Kick-Out Connector, Drawer Kick-Out drive signal