Adjusting of the minimum of the top burners

Considering that in the minimum position the flame must have a length of about 4 mm and must remain lit even with a quick turn from the maximum position to that of minimum.

The flame adjustment is done in the following way:

–Turn on the burner

–Tum the tap to the MINIMUM position

–Take off the knob

–With a small flat screwdriver turn the screw inside the tap rod to the correct regulation (fig. 40).

Normally for LPG, tighten up the regulation screw.

Fig. 40

39

Page 39
Image 39
CDA RC 9000 installation instructions Adjusting of the minimum of the top burners