Electrical installation

The appliance must be connected to the electrical network verifying above all that the voltage corresponds to the value indicated on the specifications plate and that the cables section of the electrical plant can bear the load which is also indicated on the plate.

The cooker can be connected directly to the mains placing an omnipolar switch with minimum opening between the contacts of 3 mm between the appliance and the mains.

The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 75°C at any point.

Once the cooker has been installed, the switch must always be accessible.

Before effecting any intervention on the electrical parts the appliance must be disconnected from the network.

Warning!

Electricity can be extremely dangerous.

This appliance must be earthed.

Connecting feeder cable

To connect the feeder cable to the cook- er it is necessary to:

Remove the screw that hold shield “A” behind the cooker (fig. 41).

Insert the feeder cable of the suitable section (as described in the next chap- ter) into the cable clamp “D”.

Connect the phase and earth cables to the terminal block “B” according to the diagram in figure 42.

Pull the feeder cable and block it with cable clamp “D”.

Re-mount shield “A”.

D

B

A

Fig. 41

230 V

Feeder cable section

TYPE HO5RR-F

 

L1

N PE

230 V

3 x 1,5 mm2

(L2)

Fig. 42