Table for the choice of the injectors

GB

 

 

 

 

 

 

Cat: II 2H3+

 

Nominal

Reduced

G 30 - 28-30 mbar

 

 

 

G 20

BURNERS

G 31 - 37 mbar

 

 

20 mbar

 

Power

Power

 

 

 

 

 

 

 

 

By-pass

Ø injector

By-pass

 

Ø injector

 

[kW]

[kW]

 

 

[1/100 mm]

[1/100 mm]

[1/100 mm]

 

[1/100 mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (A)

1,00

0,30

27

50

 

 

 

 

72 (X)

 

adjustable

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid (SR)

1,75

0,45

32

65

 

 

 

97 (Z)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (R)

3,00

0,75

42

85

 

 

 

 

115 (Y)

 

 

 

 

 

 

 

 

 

 

Triple-ring (TR)

3,50

1,50

65

95

 

 

 

 

135 (T)

 

 

 

 

 

 

 

 

 

 

INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m3/h x kW)

BURNERS

Air necessary for combustion [m3/h]

Auxiliary (A)

2,00

 

 

Semi-rapid (SR)

3,50

 

 

Rapid (R)

6,00

 

 

Triple-ring (TR)

7,00

 

 

Lubrication of the gas taps

The operations must be executed by a qualified technician.

IMPORTANT

All intervention regarding installation maintenance and conversion of the appliance must be fulfilled with original factory parts.

The manufacturer declines any liability resulting from the non-compliance of this obligation.