Table for the choice of the injectors
GB |
|
|
|
|
|
| Cat: II 2H3+ | ||
| Nominal | Reduced | G 30 - |
|
|
| G 20 | ||
BURNERS | G 31 - 37 mbar |
|
| 20 mbar | |||||
| Power | Power |
|
|
|
|
|
|
|
| Ø injector |
| Ø injector | ||||||
| [kW] | [kW] |
| ||||||
| [1/100 mm] | [1/100 mm] | [1/100 mm] |
| [1/100 mm] | ||||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
Auxiliary (A) | 1,00 | 0,30 | 27 | 50 |
|
|
|
| 72 (X) |
| adjustable |
|
| ||||||
|
|
|
|
|
|
|
|
| |
1,75 | 0,45 | 32 | 65 |
|
|
| 97 (Z) | ||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
Rapid (R) | 3,00 | 0,75 | 42 | 85 |
|
|
|
| 115 (Y) |
|
|
|
|
|
|
|
|
|
|
3,50 | 1,50 | 65 | 95 |
|
|
|
| 135 (T) | |
|
|
|
|
|
|
|
|
|
|
INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m3/h x kW)
BURNERS | Air necessary for combustion [m3/h] |
Auxiliary (A) | 2,00 |
|
|
3,50 | |
|
|
Rapid (R) | 6,00 |
|
|
7,00 | |
|
|
Lubrication of the gas taps
The operations must be executed by a qualified technician.
IMPORTANT
All intervention regarding installation maintenance and conversion of the appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the
40