Cecilware GB-IT Rinse Lockout ## Hrs Water Temp ### Deg F, Low Temp Lockout ### Deg F

Models: GB-IT

1 34
Download 34 pages 11.82 Kb
Page 13
Image 13
RINSE LOCKOUT

27.If the Stop key is pressed the LCD/VFD screen will display the following:

28.If the Stop key is pressed the LCD/VFD screen will display the following:

29.If the Stop key is pressed the LCD/VFD screen will display the following:

RINSE LOCKOUT

## HRS.

WATER TEMP.

### DEG F

 

TEMP LOCKOUT

TEMP LOCKOUT

 

ON

Off

 

 

 

 

 

 

30.If the ▼and ▲ keys are pressed Low Temperature Lockout will toggle between “on” and “off”.

31.If the Stop key is pressed the LCD/VFD screen will display the following:

LOW TEMP LOCKOUT

### DEG F

32.

If the Stop key is pressed the LCD/VFD screen will display the following:

 

 

HOPPER STATUS

 

 

 

 

 

SELECT A KEY

 

33.

Pressing any of the Dispense keys will cause the Dispense LED(s) of the corresponding

 

 

 

 

 

 

 

 

 

 

 

HOPPER STATUS

HOPPER STATUS

 

Hopper to blink and the LCD/VFD screen will display the status for the indicated Hopper as

 

 

ON

Off

 

follows:

 

 

 

 

 

 

 

 

 

 

 

 

34.If the ▼and ▲ keys are pressed the hopper status will toggle between “on” and “off”.

35.

If the Stop key is pressed the LCD/VFD screen will display the following:

 

 

AUGER STATUS

 

 

 

 

 

SELECT A KEY

 

36.

Pressing any of the Dispense keys will cause the Dispense LED(s) of the corresponding

 

 

 

 

 

 

AUGER STATUS

AUGER STATUS

 

Hopper to blink and the LCD/VFD screen will display the status for the indicated Auger as

 

 

ON

Off

 

follows:

 

 

 

 

 

 

 

 

 

 

 

 

37.If the ▼and ▲ keys are pressed the Auger Status will toggle between “on” and “off”.

38.

If the Stop key is pressed the LCD/VFD screen will display the following:

 

 

MIX/DUMP STATUS

 

 

 

 

 

SELECT A KEY

 

39.

Pressing any of the Dispense keys will cause the Dispense LED(s) of the corresponding

 

 

 

 

 

 

MIX/DUMP STATUS

MIX/DUMP STATUS

 

hopper to blink and the LCD/VFD screen will display the status for the indicated

 

ON

Off

 

Mixer/Dump Valve as follows:

 

 

 

 

 

 

 

 

 

 

 

 

40.If the ▼and ▲ keys are pressed the Mixer/Dump Valve Status will toggle between “on” and “off”.

41. If the Stop key is pressed the LCD/VFD screen will display one of the following:

DISPLAYED

DISPLAYED

 

UNITS ENGLISH

UNITSMETRIC

 

 

 

 

 

 

42.If the ▼and ▲ keys are pressed the Displayed Units will toggle between “English” and “Metric”.

43.If the Stop key is pressed the LCD/VFD screen will display the following:

44.Pressing the ▼and ▲ keys simultaneously will cause all parameters to revert to default values and the menu to display the following:

RESET SYSTEM ARE YOU SURE?

RESET SYSTEM

COMPLETED

13

Page 13
Image 13
Cecilware GB-IT Rinse Lockout ## Hrs Water Temp ### Deg F, Low Temp Lockout ### Deg F, Reset System Completed