CFM Corporation DVT44IN, DVT38IN General Venting, Chateau, Location of Vent Termination, 20011956

Models: DVT44IN DVT38IN

1 48
Download 48 pages 13 Kb
Page 14
Image 14
General Venting

Chateau™

White or Green

To Pilot Ignitor

Green or White

White or Orange

 

Orange or White

To Pilot

 

Flame Sensor

DC Motor

 

Pilot

 

Main

 

 

AF-4000

 

Module

 

Main

 

Learn

 

 

 

 

 

 

 

Button

Black

 

 

Power

Orange

 

 

 

Module

Red

Red

 

 

Brown

 

 

 

 

Black

Pulse/Continuous

Button

Brown

Brown

Red

Black

I

S

Remote Battery

Back-Up Pack

Remote/Off

Switch

Continuous

Pilot ON/OFF

Switch

Black

Gnd

Red

Black

 

 

 

 

(SWI) (Optional

(SWI) ON/OFF Switch)

FP1795

AC Adaptor

Extension Harness

Fig. 11 DVT38/44 wiring diagram.

General Venting

Your fireplace is approved to be vented either through the side wall, or vertical through the roof.

Only CFM Corporation venting components spe- cifically approved and labelled for this fireplace may be used.

Venting terminals shall not be recessed into a wall or siding.

Horizontal venting must be installed on a level plane without an inclining or declining slope.

There must not be any obstruction such as bushes, gar- den sheds, fences, decks or utility buildings within 24” (610 mm) from the front of the termination hood.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent ac- cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative the vent termination be located observ- ing the minimum clearances as shown on following page.

14

20011956

Page 14
Image 14
CFM Corporation DVT44IN, DVT38IN installation instructions General Venting, Chateau, Location of Vent Termination, 20011956