Special Feature for Cold Climates

 

Learn

 

Button

 

AUX

Learn

Junction Box

POWER

 

 

IPI

 

Continous

S

I

Pilot

ADJ.

 

Off/On Remote/Off

 

Main Module

Power Module

Main Module

FP1792

 

Fig. 10 Connect 120V AC electrical supply.

16.If you chose to install the optional back-up battery pack (No. DVTBBK), you must install a wall box within 15 feet (4.6 m) of the fireplace. Assemble the connectors on one end of the supplied extension wire harness to the mating connectors on wire har- ness within the control box. Make sure to connect black coded wire to black and red coded wire to red.

17.The other end of the extension wire harness should be connected to the wiring of the back-up battery holder located within a wall box.

18.Insert the supplied four (4) “AA” batteries into the battery older. Be sure to note correct polarity for each battery.

19.Mount electrical wall box containing back-up bat- teries at a convenient location with 15 feet (4.6 m) of the fireplace. Cover wall box using a blank wall plate.

20.The fireplace remote system is ready for use.

21.Reassemble access panel, burner assembly, gas supply connector, brick panels, logs, embers, andirons and lava rock in reverse order of removal. (Refer to Log, Lava Rock and Ember Placement section.

22.Turn on gas supply and check that all connections are tight and leak free.

Chateau™

NOTE: If you need to test the inlet pressure and/or manifold pressure, there are two (2) test ports available along the right side front edge between the firebox side and outer casing. The upper test port is inlet pressure. The lower test port is manifold pressure. (Refer to Figure 8)

CAUTION: Turn off the gas supply before removing test port plug.

23.Using a 7/16” nut driver, remove the threaded plug from the test port.

24.Thread the supplied extension adaptor into the open test port.

25.Attach a 1/4” diameter pressure gauge flexible hose fully onto the barb of the adaptor.

26.Turn on gas supply and operate valve with remote control as needed to indicate gas pressure.

CAUTION: Turn off the fireplace and gas supply before removing test port adaptor and replacing plug.

27.After test, remove extension adaptor and replace plug securely.

28.Turn on gas supply and check that plugs are tight and leak free.

Special Feature for Cold Climates

This gas control system has the option of a continu- ous pilot feature. This allows the user to change from a spark to pilot system to a standing pilot system for direct vent appliances during cold climate conditions to keep the firebox warm.

When the continuous pilot mode is activated and the fireplace is turned ON, the pilot will spark and light. When the fireplace is turned OFF, the pilot will stay ON when the main burner shuts OFF.

The continuous pilot mode can be activated or de-acti- vated by the hand held remote control transmitter.

20011956

9

Page 9
Image 9
CFM Corporation DVT38IN, DVT44IN installation instructions Special Feature for Cold Climates, Chateau, 20011956