Table 1

Chateau™

 

 

 

Table 1

Injector Orifice Size Matrix

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion to LP

 

 

 

 

 

 

 

 

 

Burner Orifice

 

 

Input (BTU/hr)

Kit #

Model

Front

Part #

 

Middle

Part #

Rear

Part #

Minimum

Maximum

20011992

DVT38IP

#66

20009182

 

#59

20000664

#50

30000337

34,000

46,000

 

 

(.033”)

 

 

(.041”)

 

(.070”)

 

 

 

20012367

DVT44IP

#63

20006251

 

#57

20004587

#49

20006252

45,000

60,000

 

 

(.037”)

 

 

(.043”)

 

(.073”)

 

 

 

Table 2 Air Shutter Settings

Conversion to LP

 

Burner Tube

Burner Housing

Model

Air Shutter Setting

Air Shutter Setting

DVT38IP

Fully open

n/a

DVT44IP

Fully open

Fully open

Table 3 Valve Minimum Rate Screw

Model

Size

Part #

DVT38IP

#31 (.120”)

20012364

DVT44IP

No Shank Screw

20012264

Pilot Flame Adjustment

Typically, the top 3/8” or 1/2” of the pilot flame sensor should be engulfed in the pilot flame. (Page 28, Fig. 50)

To adjust pilot burner:

1.Locate pilot adjustment screw on the valve next to the black plastic cap. Refer to Page 30.

2.Adjust pilot screw to provide proper sized flame. Only a small adjustment should be needed.

NOTE: Do not rotate screw excessively. Do not adjust any other screws on the valve.