INSTALLATION STEP 6
Install the Door ControlLocate door control within sight of the door at a minimum height of 1.5 m where small children cannot reach, and away from moving parts of the door and door hardware. The installation surface must be smooth and flat. If installing into drywall (Figure 1), drill 4 mm holes and use anchors provided. For
NOTE: After installation, a green indicator light behind the cover will indicate proper connection. If not lit, the Lock and Light features will not function (reverse wires to correct).
1.Strip 11 mm of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to 2 and white/red wire to the 1 (Figure 3).
2.Model 1215E - Lighted door control: Remove the cover from the Lighted Door Control. Fasten to wall with
Model 1225E -
•Drill and install bottom screw, allowing 3 mm to protrude above wall surface.
•Position bottom of door control on screw head and slide down to secure. Adjust screw for snug fit.
•Install top screw with care to avoid cracking plastic housing. Do not overtighten.
•Insert bottom tabs and snap on cover.
3.(Standard installation only) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do not pierce wire with a staple, creating a short or open circuit.
4.Strip 11 mm of insulation from end of bell wire. Connect bell wire to the
NOTE: When connecting multiple door controls to the opener, twist same color wires together. Insert wires into
5.Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in a prominent location on inside of garage door.
WIRING INSTRUCTIONS FOR ACCESSORIESThe Protector System®: To opener terminals: White to White and Black to grey.
Outside Keylock Accessory connections: To opener
terminals: Red/white to Red and White to White.
WARNING
To prevent possible SERIOUS INJURY or DEATH from electrocution:
•Be sure power is not connected BEFORE installing door control.
•Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
•Install door control within sight of garage door, out of reach of children at a minimum height of 1.5 m, and away from all moving parts of door.
•NEVER permit children to operate or play with door control push buttons or remote control transmitters.
•Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
•ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.
HARDWARE SHOWN ACTUAL SIZE
|
|
|
| Lighted Door Control Button |
|
|
|
|
|
|
|
|
|
|
| Insulated |
| ||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Staples |
| |||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Drywall |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||
|
| 6AB x |
| Anchors | |||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| STANDARD |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||
Figure 1 INSTALLATION | Figure 2 INSTALLATION |
Single
Gang Box
| LOCK |
|
|
|
|
| LIGHT |
|
| LOCK |
|
To Replace |
|
| LIGHT |
| |
|
|
| 24 Volt | ||
Insert Bottom Tabs First | To Replace |
| |||
| Bell Wire | ||||
|
| Insert Bottom Tabs First | |||
|
|
| |||
Figure 3 DOOR CONTROL (BACK) | Figure 4 REMOVE COVER | ||||
| Top Mounting Hole |
|
|
| |
| Terminal |
|
|
|
|
| Screws |
|
|
|
|
WH | T |
|
|
|
|
RED WHT |
|
|
| ||
|
|
|
| ||
| 1 | 2 |
|
|
|
RED |
|
|
|
| |
| Bell Wire |
|
|
| |
|
|
|
|
| |
| Bottom Mounting Hole |
|
|
| |
Figure 5 |
|
|
|
| |
|
| Door Control |
| To release wire, push in tab | |
|
| Connections |
| with screwdriver tip |
Red White Grey
11 mm
Strip wire 11 mm
22