WIRE SAFETY REVERSING SENSOR

 

Option B: Installation With Pre-Wiring

 

 

3.1b Cut Safety Reversing Sensor Wires

3.2b Strip Safety Reversing Sensor Wires and

 

 

Pre-Installed Wires

Cut the end of the safety sensor wire, making sure there is enough wire to reach the pre-installed wires from the wall.

3.3b Connect Wires Together

Connect the pre-installed wires to the sensor wires with wire nuts making sure the colors correspond for each sensor. For example, the white wire would connect to the yellow wire and the white/black wire would connect to the purple wire.

Safety sensor wires

Separate the safety sensor wires and strip 7/16 inch (11 mm) of insulation from each end. Choose two of the pre-installed wires and strip 7/16 inch (11 mm) of insulation from each end. Make sure that you choose the same color pre-installed wires for each sensor.

Safety

7/16"

Pre-installed wires

sensor

(11 mm)

wires

 

 

7/16" (11 mm)

Not Provided

 

Yellow

Pre-installed

White

(for example)

 

wires

 

 

 

White/Black

Purple (for example)

 

 

3.4b Connect Like Colored Wires Together

3.5b Connect Wires to Garage Door Opener

At the garage door opener, strip 7/16 inch (11 mm) of insulation from each end of the wires previously chosen for the safety sensors. Twist the like-colored wires together.

Yellow

Purple

7/16" (11 mm)

Insert the wires that are connected to the white safety sensor wires to the white terminal on the garage door opener. Insert the wires that are connected to the white/black safety sensor wires to the grey terminal on the garage door opener.

Purple

Yellow (for example) (for example)

To insert or remove the wires from the terminal, push in the tab with a screwdriver tip.

20