RADIO RECV

Convenience terminals provide power and contact connection for a

 

radio receiver. Activation is the same as CYCLE.

OBSTRUCTION ALARM (TB17)

 

Relay contacts close to provide 24VDC alarm power if the gate has two

 

consecutive obstruction faults.

LOW BATTERY/ NO AC POWER (TB18)

LOW BATTERY

Activation fully opens or closes the gate, depending the setting of

 

Switch S3.

NO AC POWER

Activation registers the date and time of power outages in the gate

 

operator transaction buffer.

24VAC OUTPUT (TB7)

Terminals provide power (24VAC, 200mA) for peripheral

devices.

 

 

MAGLOCK INPUT (TB4)

 

MAGLOCK

Relay contacts close when the gate is fully closed.

SLAVE I/O INPUT (TB1)

 

SLAVE I/O

Input/output terminals are used to control a second gate operator in a

 

Master/Slave system.

PHONE LINE (J9)

Terminals connect the telephone line to the gate operator.

 

 

 

ADJUSTMENTS

 

 

OBSTRUCTION

Adjustable pot controls gate sensitivity to blockages by the

RIGHT (R69) instantaneous rise in motor current. When the limit is exceeded, the

 

gate reverses a programmed distance (minimum 2 inches).

OBSTRUCTION

Adjustable pot controls gate sensitivity to blockages by the

LEFT (R160)

instantaneous rise in motor current. When the limit is exceeded, the

 

gate reverses a programmed distance (minimum 2 inches).

NOTE: LiftMaster gate operators have two obstruction sense adjustments (left and right)

 

where other gate operators have only one. This allows greater flexibility

 

of installation. For instance, you can install a gate on an incline and not

 

worry about sacrificing downhill gate sensitivity.

START-UP

Adjustable pot controls the delay in sensitivity to gate

(R203)

obstructions. This delay in sensitivity prevents the initial motor

 

inrush current from causing a obstruction fault. The weight of the gate

 

determines this setting.

CONNECTORS

LIMIT SWITCH (J4) Connector for the left/right limit switch cable.

PWR INPUT (J1) Connector for AC input power.

MOTOR POWER (J3) Connector for the motor cable.

LOOP DETECTOR

Connector for the optional LiftMaster Outside Interrupt Loop

(J15)

detector add-on board.

LOOP DETECTOR

Connector for the optional LiftMaster Inside Interrupt Loop

(J12)

detector add-on board.

LOOP DETECTOR

Connector for optional LiftMaster Shadow Loop detector add-

(J13)

on board.

LOOP DETECTOR

Connector for optional LiftMaster Exit Loop detector add-on

(J14)

board.

OBSTRUCTION

Connector for factory-installed alarm.

(TB17)

 