This is a seven segment character display that gives numerical response to service personnel during programming and operation.
Indicates that the LEFT limit switch is activated. Indicates that the RIGHT limit switch is activated.
Indicates data is being received from the other unit in a Master/ Slave system.
Indicates data is being sent to the other unit in a Master/Slave system.
Indicates the gate operator is off hook and using the phone line.
Indicates the peak or average motor current threshold was reached and the motor was stopped. See Fault List. Indicates Interrupt Bar (Edge Sensor) switch was activated and the motor was stopped.
Indicates the motor is engaged, but is not drawing any current. The thermal overload switch on the motor may need to be reset. See Fault List.
Indicates that a limit switch is stuck closed.
Indicates the motor ran for 75 seconds without reaching a limit switch and was stopped. Usually requires mechanical service. See Fault List.
Indicates an incoming telephone call ring detect and whether the phone line is available when the gate operator wants to initiate a call.
Indicates the gate is moving counterclockwise. Indicates the gate is moving clockwise. Indicates the Mag Lock is engaged.
Indicates the Obstruction Alarm has sounded after two consecutive gate obstruction faults.
APPENDIX A
SYSTEM OPERATION REFERENCE
CONTROLS, INDICATORS, INPUTS AND ADJUSTMENTSFor control and indicator locations, refer to Figure 17. For detailed explanations of the Gate Operator’s various controls, indicators inputs and adjustments, refer to the following pages.
CONTROLSKEYPAD | The 12-key keypad is used for local operation, programming and |
| service. |
SWITCH S2 | |
GATE OPEN TO | Selects the direction the gate will open (LEFT/RIGHT). |
LEFT/RIGHT | |
SWITCH S3 | |
LOW BATTERY | Selects the direction the gate will move (left/right) and remain |
LEFT/RIGHT | there, when the Low Battery input is activated by an |
| Uninterruptible Power Supply (UPS). |
INDICATORSLED indicators light when controls and inputs are active. Additional indicators are as follows:
DISPLAY
LEFT LIMIT
RIGHT LIMIT
RECV
XMIT
OFF HOOK
OBSTRUCTION
INTERRUPT BAR (EDGE SENSOR) OPEN MTR
STUCK LIMIT
MAX RUN TIME
LINE
MTR LEFT
MTR RIGHT
MAG LOCK
OBSTRUCTION
ALARM
Rev J | Doc 01-20098 | Page 34 of 44 |