IF GATE TYPE IS SWING OR LINEAR (ATG IS NOT FUNCTIONAL):
Inside Interrupt Loop:
Activation stops an opening or closing gate and deactivation opens the gate.
Outside Interrupt Loop:
Activation opens a closing gate.
IF GATE TYPE IS SLIDE OR BARRIER AND ATG IS OFF: Inside Interrupt Loop:
Activation opens a closing gate. Outside Interrupt Loop:
Activation opens a closing gate.
IF GATE TYPE IS SLIDE OR BARRIER AND ATG IS ON: Inside Interrupt Loop:
Activation/deactivation closes an opening gate. Activation stops a closing gate and deactivation closes the gate.
Outside Interrupt Loop:
Activation stops a closing gate and deactivation closes the gate.
INSIDE/OUTSIDEIF GATE TYPE IS SWING OR LINEAR:
Inside Photo Sensor:
Activation stops a moving gate and deactivation restarts the gate. Outside Photo Sensor:
Activation stops a closing gate and deactivation restarts the gate.
IF GATE TYPE IS SLIDE OR BARRIER:
Inside Photo Sensor:
Activation stops an opening gate and deactivation restarts the gate.
Outside Photo Sensor:
Activation stops a closing gate and deactivation restarts the gate.
INTERRUPT BAR INPUTS (TB11)INTERRUPT BAR Activation causes gate to stop and reverse a few inches.
INS./OUTS. INT. SENSE / SHADOW SENSE / EXIT SENSE (TB12/TB13/TB14/TB15)INPUTS |
|
|
INSIDE | Input from an Inside Interrupt loop provides the signal for an | |
INTERRUPT | optional LiftMaster loop detector | |
| same as the Interrupt Loop SENSE input, above. | |
OUTSIDE | Input from an Outside Interrupt loop provides the signal for an | |
INTERRUPT | optional LiftMaster loop detector | |
| same as the Interrupt SENSE | Loop input, above. |
SHADOW | Input from shadow loop provides signal for optional LiftMaster loop | |
SENSE | detector | |
| input, above. |
|
EXIT | Input from exit loop provides signal for optional LiftMaster loop | |
SENSE | detector | |
| above. |
|
Rev J | Doc | Page 36 of 44 |