INSTALLATION STEP 7

Install the Battery Backup

• Make sure motor unit is unplugged.

Using a Phillips head screwdriver, remove the battery

 

cover on the motor unit.

Partially insert battery into motor unit with terminals

 

facing out.

ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.

• Connect the red (+) and black (-) wires from motor unit

 

to corresponding terminals on battery.

Verify the battery wires are seated in the channel.

Replace battery cover.

INSTALLATION STEP 8

Channel

Battery

Battery Cover

Install the Lights

Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens.

Install a 100 watt maximum light bulb in each socket. Light bulb size should be A19, standard neck only. The lights will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the lights will turn OFF.

Reverse the procedure to close the lens.

Use A19, standard neck garage door opener bulbs for replacement.

NOTE: Use only standard light bulbs. The use of short neck or speciality light bulbs may overheat the endpanel or light socket.

To prevent possible OVERHEATING of the endpanel or light socket:

DO NOT use short neck or specialty light bulbs.

DO NOT use halogen bulbs. Use ONLY incandescent. To prevent damage to the opener:

DO NOT use bulbs larger than 100W.

ONLY use A19 size bulbs.

100 Watt (Max)

Standard Light Bulb

Release Tab

Lens

100 Watt (Max)Hinge

Standard Light Bulb

18