( This page is for information only - Consult your Installer for Application )

VR1

502

IR FREQ

IR Emitter Modulation Frequency - these are factory set to give optimum preformance of the emitters. Factory setting is 40KHz.

Range is 32 KHz full CCW to 65 KHz full CW.

IR OUTPUT PC BOARD (Fig. #1)

502502

502

Doorbell Level - adjust to onboard doorbell chime to appropriate level. Factory setting -10db

DOORBELL/PAGING PC BOARD (Fig. #2)

Page Sensitivity - set to match page source output for VOX function. Factory setting -20db.

INDIVIDUAL ZONE PC BOARDS (Fig. #3)

Switch - mutes sources when doorbell or page is engaged. Factory setting is “on”. Set to “off” if you don’t wish to have sources muted when doorbell or page is activated (such as a nursery, etc.).

Page Level - adjust to set page level to appropriate level. Factory setting is -10db.

Audio - disables doorbell and page audio. Factory setting is “on”.

If you want one zone to not be interrupted by paging or the dorrbell, set both switches to “off”.

If you wish to have one zone muted without the doorbell or paging audio set audio switch to “off”.

If you want to leave the source audio in place and have the page and doorbell audio superimposed over the top of it, set switch to “off”.

Page 3

Page 11
Image 11
Channel Plus MDS-6 manual DOORBELL/PAGING PC Board Fig. #2