DANGER

NEVER store a spare LP tank under or near grill or in enclosed areas.

Never fill the cylinder beyond 80% full. An overfilled spare LP tank is hazardous due to possible gas released from the safety relief valve. The safety relief valve on a LP tank could activate releasing gas and cause a fire.

If you see, smell or hear escaping gas, immediately get away from the LP tank/grill and call your fire department.

All spare LP tanks must have safety caps installed on the LP tank outlet.

4.Brush soapy solution onto following connections:

LP Tank Removal, Transport And Storage

Turn OFF all control knobs and LP tank valve. Turn coupling nut counter clockwise by hand only - do not use tools to disconnect. Lift LP tank wire upward off of LP tank collar, lift LP tank up and off of support bracket. Install safety cap onto LP tank valve. Always use cap and strap supplied with valve. Failure to use safety cap as directed may result in serious personal injury and/or property damage.

LP Tank

 

Safety

Valve

Retainer

Cap

 

Strap

 

A disconnected LP tank in storage or being transported must have a safety cap installed (as shown). Do not store an LP tank in enclosed spaces such as a carport, garage, porch, covered patio or other building. Never leave a LP tank inside a vehicle which may become overheated by the sun.

Do not store LP tank in an area where children play.

Leak Testing Valves, Hoses and Regulator

1.Turn all grill control knobs to OFF.

2.Be sure regulator is tightly connected to LP tank.

3.Completely open LP tank valve by turning hand wheel counter clockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before proceeding.

5."If growing" bubbles appear, there is a leak. Close LP tank valve immediately and retighten connections. If leaks cannot be stopped "do not try to repair." Call for replacement parts.

Order new parts by giving the serial, model number and name of items needed to the Grill Service Center at !1-800-241-7548 U.S. or 1-800-387-6057 CAN.

6.Always close LP tank valve after performing leak test by turning hand wheel clockwise.

Safety Tips

Before opening LP tank valve, check the coupling nut for tightness.

When grill is not in use, turn off all control knobs and LP tank valve.

Never move grill while in operation or still hot.

When moving the grill push it forward, do not pull from behind.

Use long-handled barbecue utensils to avoid burns and splatters.

Do not remove grease receptacle or tray until grill has completely cooled.

If you notice grease or other hot material dripping from grill onto valve, hose or regulator turn off gas supply at once. Determine the cause, correct, clean and inspect valve, hose and regulator before continuing. Perform a leak test.

The regulator may make a humming or whistling noise during operation. This will not affect safety or use of grill.

If you have a grill problem see the "Troubleshooting Section".