Excalibur electronic P95-LP3 Installation, Pilot Adjustment, High Elevation, Max. Input Rating

Models: P95-NG3 P95-LP3

1 44
Download 44 pages 25.34 Kb
Page 23
Image 23
Burner Inlet Orifice Sizes: #30

INSTALLATION

P95-NG3 System Data

For 0 to 4500 feet altitude

Burner Inlet Orifice Sizes: #30

Max. Input Rating

45,000 Btu/h

Min. Input Rating

23,200 Btu/h

 

 

Supply Pressure

min.5.0" w.c.

Manifold Pressure

 

(High)

3.8"+/- 0.2"w.c.

P95-LP3 System Data

For 0 to 4500 feet altitude

Burner Inlet Orifice Sizes: #49

Max. Input Rating

40,000 Btu/h

Min. Input Rating

22,400 Btu/h

 

 

Supply Pressure

min.12.0" w.c.

Manifold Pressure

 

(High)

11"+/- 0.2" w.c.

Electrical: 120 V A.C. System.

Circulation Fan: variable speed 200 CFM.

Log Set: Ceramic fi bre, 7 per set.

Vent System: Simpson Dura-Vent Direct Vent System or FPI Flex System.

For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.

When using copper or fl ex connectors use only approved fi ttings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and fl ex connectors are usually considered to meet this requirement.

Important:Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing.

PILOT ADJUSTMENT

Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile, 1 around the thermocouple and 1 flowing across the burner (it does not have to be touching the burner).

Note: If you haveanincorrectflamepattern, contact your Excalibur® dealer for further instructions.

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear burner or thermopile or thermocouple.

Themanifoldpressureiscontrolledbyaregulator built into the gas control, and should be checked at the pressure test point.

Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" position.

2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counter clockwise with a 1/8" wide fl at screwdriver.

3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

4)Light the pilot and turn the valve to "ON" position.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.

6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten.

S.I.T. VALVE DESCRIPTION

HIGH ELEVATION

This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1 2.17-M91) & U.S.A ANSI ZZ1.88a

1)Gas on/off knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection - option

5)Outlet Pressure Tap

6)Inlet Pressure Tap

7)Pilot Outlet

8)Main Gas Outlet

9)Alternative TC Connection Point

GAS LINE

INSTALLATION

The gas line is brought in through the left side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve.

Note: When the gas line is being installed from the left side, be sure to leave room to accommodate servicing of the fan.

The gas line connection may be made of rigid pipe, copper pipe or an approved flex connector. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.

GAS PIPE PRESSURE

TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace

23

Page 23
Image 23
Excalibur electronic P95-LP3 Pilot Adjustment, High Elevation, Gas Line Installation, Gas Pipe Pressure Testing