Excalibur electronic P95-LP3 Installation of the DC Sparker, Piezo Ignitor, Ignitor Wire

Models: P95-NG3 P95-LP3

1 44
Download 44 pages 25.34 Kb
Page 25
Image 25
Do not overtighten the screw. Recommended to

INSTALLATION

12)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

WARNING!

Do not overtighten the screw. Recommended to

grip the wrench by the short side.

16)Verify that if the conversion is from NG to LPG, the screw must be re- assembled with the red o-ring visible (Fig. 5).

Installation of the DC Sparker:

15)Locate the Piezo Ignitor situated at the side of valve.

Piezo

Ignitor

Fig.2

Red o-ring visible

Fig.5

LPG Configuration

16)RemovethePiezoIgnitorbyunscrewingthe nut at the back of the mounting bracket.

Ignitor

Wire

13)Check that the screw is clean and if necessary remove dirt.

14)Flip the screw (Fig. 3).

Fig.3

17)Re-assemble the black protection cap (Fig. 6).

Fig. 6

Piezo

Ignitor

17)Disconnect the ignitor wire from the Piezo Ignitor and connect it to the DC Sparker.

DC

Sparker

Ignitor

Wire

15)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.

Fig.4

18) Install the 3/4" nylon plug to cover up the hole on the mounting bracket.

WARNING!

Also check that the pilot and main
burner injectors

are appropriate for the gas type.

12)Reverse steps 6) to 1).

13)Attach the label "This unit has been converted to LPG near or on top of the serial # decal.

14)Replace yellow "Natural Gas" label with red "LPG" label.

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace

25

Page 25
Image 25
Excalibur electronic P95-LP3, P95-NG3 Installation of the DC Sparker, Do not overtighten the screw. Recommended to