SECTION 3 – INSTALLATION

3-1. Installing Work Clamp

1 Insulator

1

2 Bolt

Tools Needed:

3 Smaller Hole

4 Work Clamp Tabs

Bend tabs around work cable.

5 Work Cable From Unit

6

2

6 Nut

5

3/8, 7/16 in

3

4

Ref. ST-025 190-D

3-2. Installing Welding Gun And Changing Polarity

Tools Needed:

5/16 in

.Follow wire manufacturer’s recommendation.

 

Solid Steel Or

Flux Cored Wires

Aluminum Wires

(FCAW–Without Gas)

(GMAW–With Gas)

 

5

Straight Polarity

Reverse Polarity

DCEN

DCEP

2

1 3

4

1Drive Assembly

2Gun Securing Bolt

3Gun End

Loosen securing bolt. Insert gun end through opening until it bottoms against drive assembly. Tighten bolt.

4 Gun Trigger Plug

Insert plug into receptacle, and tighten threaded collar.

5 Jumper Links

Place jumper links in position shown for desired polarity.

Close door.

Ref. ST-801 987

OM-1318 Page 11

Page 15
Image 15
Miller Electric 172 M-10 Gun manual Installation, Installing Work Clamp, Installing Welding Gun And Changing Polarity