OM-1318 Page 18
SECTION 5 – MAINTENANCE &TROUBLESHOOTING
5-1. Routine Maintenance
YDisconnect power before maintaining.
3 Months
Replace
unreadable
labels.
Repair or
replace
cracked
weld cable.
Clean and
tighten weld
terminals.
6 Months
Blow out or
vacuum inside.
during heavy
service, clean
monthly.
Or
Remove drive roll
and apply light coat
of oil or grease to
drive motor shaft.
5-2. Drive Motor Fuse F1
YT urn Off power , unlatch door
and remove wrapper.
1 Circuit Board PC1
2 Fuse F1 (See Parts List For
Rating)
If drive motor is inoperative, pull
fuse from fuse holder on PC1. Re-
place fuse if necessary. To reinstall,
push fuse into fuse holder.
Reinstall wrapper, and latch door.
ST-801 867
3/8 i n
Tools Needed:
12