INSTALLATION

The P95-3 is approved for a maximum 40 ft. straight vertical, with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas, as per the diagram.

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas. Maximum two 45o elbows allowed.

Vent must be supported at offsets

• Firestops are required at each floor level and whenever passing through a wall.

Maintain clearances to combustibles as listed in the "Clearances,"

"Locating Your Gas Fireplace," "Combustible Mantels," "Unit Base Stand-offs,""FramingandFinishing,""FacingRequirement,"&"Hearth Requirement" sections.

Please note that all vertical measurements are taken from the base of the unit excluding risers or bottom stand-offs.

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace