INSTALLATION

OPTIONAL COVER PLATE TEMPLATE

1)Ensure top clip screws are at top of oblong holes before installation.

Oblong Screw

Holes

2)Position bottom of cover plate over pins located at the bottom of the fi rebox.

Pins

3)Bring cover plate towards the unit and hook top clip over and behind the glass frame.

Thetopclipmayneedtobeadjusted.Loosen the 2 screws that secure the top clip to let the cover plate settle over and behind the glass frame. Once settled tighten screws.

Top Clip

Back View of

Cover Plate

Pin Holes

TO REMOVE:

1)Remove 2 screws that secure top clip. Ensure to hold cover plate as it will fall forward.

2)Pull out top clip that is still hooked onto glass.

UNIT ASSEMBLY

PRIOR TO

INSTALLATION

The 2Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position.

Top Standoff Assembly

The top standoffs are shipped in a fl at position and must be folded into shape and attached.

1)Remove the standoffs from the fi replace top.

2)Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the pre- punched screw holes on the fi replace top line up.

3)Attach the standoff securely to the top with 2

screws per standoff (on opposite corners).

Side Nailing Strips

The side nailing strips come attached to the unit. There are 2 plates, one on the top and bottom that can be folded out as required.

Plates can be

folded out.

VENTING

INTRODUCTION

The P95-3 uses the "balanced flue" technology Co-axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be

connected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems areprohibited(see"SimpsonDura-VentVenting" section for more details and exceptions).

10

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace

Page 10
Image 10
Excalibur electronic P95-NG3, P95-LP3 Unit Assembly Prior to Installation, Venting Introduction, Top Standoff Assembly