Excalibur electronic P95-NG3 Installation, Horizontal Venting with Two 2 90o Elbows, Option

Models: P95-NG3 P95-LP3

1 44
Download 44 pages 25.34 Kb
Page 16
Image 16
Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

With

these options,

A)

0'

Min.

2' Max.

maximum total pipe length

 

 

 

 

is 30 feet with minimum

B)

1'

Min.

3' Max.

 

 

 

 

of 6

feet total vertical

C)

2'

Min.

4' Max.

and maximum 8 feet total

D)

3'

Min.

5' Max.

horizontal.

E)

4'

Min.

6' Max.

Please note minimum 1

F)

5'

Min.

7' Max.

 

 

 

 

foot between 90o elbows

G)

6' Min.

8' Max.

is required.

 

 

 

 

 

 

 

 

 

 

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 H + H1

A)0' Min. 1' Max. 1' Min. 2' Max.

B)1' Min. 2' Max. 3' Min. 3' Max.

C)2' Min. 2' Max. 5' Min. 4' Max.

D)3' Min. 2' Max. 7' Min. 5' Max.

E)4' Min. 3 Max. 9' Min. 6' Max.

F)5' Min. 4' Max. 10' Min. 7' Max.

G)6' Min. 5' Max. 11' Min. 8' Max.

H)7' Min. 6' Max. 12' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.