INSTALLATION

VENTING

FPI Direct Vent System Flex Horizontal Terminations Only

These venting systems, in combination with the P95-3 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.

FPI Direct Vent Flex System Termination Kit (Part # 946-615) includes all the parts needed to install the P95-3 with a maximum run of 4 feet.

1)8" dia. fl exible liner (4 ft. length)

2)5" dia. fl exible liner (4 ft. length)

3)spring spacers (4)

4)thimble (2)

5)AstroCap XL termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" Drill Point, Stainless Steel (4)

10)vinyl siding standoff

If longer runs are needed, the FPI Direct Vent system (Flex) kit is (Part # 946-616) which includes all the parts needed to install the P95-3 with a maximum 10' run.

1)8" dia. fl exible liner (10 ft. length)

2)5" dia. fl exible liner (10 ft. length)

3)spring spacers (7)

4)thimble (2)

5)AstroCap XL termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" Drill Point, Stainless Steel (4)

10)vinyl siding standoff

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from FPI may be used for Flex installations.

3)Horizontal vent must be supported every 3 feet.

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace