Excalibur electronic P95-LP3 Installation, Facing Requirement, Hearth Requirements, materials for

Models: P95-NG3 P95-LP3

1 44
Download 44 pages 25.34 Kb
Page 9
Image 9
4) Note: The unit does not

INSTALLATION

4) Note: The unit does not

have to be completely

enclosed in a chase. The

clearance on top of the

unit is 0" to the standoffs

so combustible building

materials can be laid

directly on top of the

standoffs. You

must

maintain clearance from

the vent to combustible

materials for

both

rigid and flex, see the

"Clearances" section.

Combustible

Material

-combustible

Material

Non

 

2"

2-1/4”

Header

 

 

 

11” dia. hole

 

 

through wall

 

 

for Flex

 

 

or for DuraVent

 

 

C

 

 

L

 

48-3/4”

53-3/4”

 

2-7/8”

 

4"

21-1/8” (533mm)

 

Facing Over 1" (25mm) Thick

If the facing material is over 1" (25mm) thick (example: brick or river rock), install the facing around the perimeter of the face. You may wish to make a face template as shown on the diagram.

FPI offers a cover plate template. See the "Optional Cover Plate Template" section.

Gas connection

on this side

Note: 53-3/4" is the minimum height for both flex termination or Simpson Dura-Vent venting.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.

NOTE: If using a brick hearth, the fi replace will need to be raised to accommodate the brick thickness. Example: If the brick is 2" thick, the unit must be raised 1".

FACING REQUIREMENT

This fi replace requires a non-combustible material extending from the framing header and sides.

The fl anges on the front face of the fi replace are for a facing thickness of 1" (25mm).

Please note thatall vertical measurements are taken from the base of the unit excludingrisersorbottom stand-offs.

HEARTH REQUIREMENTS

Floor Mounted Fireplaces

Raised Fireplaces

No hearth is required when the unit is raised 3" (76mm) off of the floor surface

 

You

must

take

 

into

account the

 

depth of the fl oor

 

covering (carpet,

 

tile,

linoleum,

etc.)

Fireplace

when determining

the

height of the

Stand

fi replace stand.

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace

9

Page 9
Image 9
Excalibur electronic P95-LP3 Installation, Facing Requirement, Hearth Requirements, Note The unit does not, standoffs. You