Miele CVA615 manual 5.43Waterpath & Flowmeter - Testing, 5678 34

Models: CVA615

1 104
Download 104 pages 36.29 Kb
Page 94
Image 94
5.43Waterpath & Flowmeter - Testing

CVA615 Coffee System

Technical Information

5.43Waterpath & Flowmeter - Testing

Caution!

Hot water will flow from the water spout during this procedure.

1.Fill the water reservoir.

2.Place the appliance into the Service Mode with the Selector Knob in the Programming position. Refer to Section 6 – Fault Diagnosis for further information on service mode access.

3.Press and hold all three coffee buttons; the display shows the following:

5678

34

Does a pulsing (flickering) “8” appear in the top line of the display?

NO

YES

 

Normal Operation – Proceed to

 

Step 6

Does water flow from the Hot Water Spout?

NO

The water is not flowing through the water path - check pump operation and water path for obstructions.

Correct fault & repeat test starting at step 1.

YES

a. Unplug JP25 from the CPU Electronic

b. Place a jumper between pins 2 & 3 (Figure 5-49).

c. Place the appliance into the Service Mode with the Selector Knob in the Programming position.

Does the display show a solid “8” in the top line of the display?

NOYES

Replace the

Replace the

electronic

flowmeter

94

Page 94
Image 94
Miele CVA615 manual 5.43Waterpath & Flowmeter - Testing, 5678 34