4.20.1Water Intake

CVA615 Coffee System

Technical Information

4.20.1Water Intake

The Pump takes in water from the water tank. (The Pump is fitted with a safety valve which opens at approx. 16 bar (232 psi) system pressure. If the pressure is too high and the safety valve opens, water is drained off via a hose to the drip tray).

4.20.2Water Path - Coffee

The water is then pumped under pressure through the Flowmeter, and through the Coffee Flow Through Heater. The water is then passed through the Water Valve, into the Brew Unit.

4.20.3Water Path – Hot Water

The Pump moves water under pressure through the Flowmeter, and through the Coffee Flow Through Heater. The water is then passed via the Hot Water Valve to the Hot Water Outlet.

4.20.4Water Path – Steam

The pump moves water under pressure via the Flowmeter and through the Coffee Flow Through Heater. When the user selects steam; the Electronic energizes the Steam Valve. Water continues flowing through the Steam Flow Through Heater. Steam is then dispensed from the frothing nozzle.