5.21Brew Unit – Removal (NOT in Start/Home Position)

CVA615 Coffee System

Technical Information

5.21Brew Unit – Removal (NOT in Start/Home Position)

Warning!

This procedure will remove the brew unit from the appliance without damages. However, after the brew unit is removed, the drives must be carefully inspected (and repaired if necessary) then placed into the start (home) position via the service mode.

Before proceeding close the front door, turn the power on to initiate a drive reset during the start-up sequence.

Once “Ready...” is displayed; open the front door and attempt to Remove the Brew Unit – Refer to Section 5.20. If the brew unit still cannot be easily removed, perform the following:

Refer to Figures 5-17 – Brew Unit and 5-18 – Brew Unit Connection Socket Retaining Screw and Locking Tab on the next page…

1.Open front door - Remove the Waste Container.

2.Locate the Philips screw (Figure 5-17, Item 2).

3.Remove the Philips screw.

4.Use a small flat tip screwdriver to left up on the locking tab (Figure 5- 18).

5.Grasp the brew unit handle and pull the brew unit out till the connection socket on the brew unit (Figure 5-17, Item 1) unsnaps from the brew unit and remains inside the appliance attached to the water nozzle.

6.Remove the Brew Unit – Refer to Section 5.20.

7.Slide the connection down to remove it from the appliance.

8.Re-install the connection socket to the Brew Unit.

9.Carefully inspect the drives for defects.

10.Test the Home Position Switch and Brewing Position Switch for proper operation.

65

Page 65
Image 65
Miele CVA615 manual 5.21Brew Unit – Removal NOTin Start/Home Position