5.45Water Path Connections - Opening

CVA615 Coffee System

Technical Information

5.45Water Path Connections - Opening

Danger!

Risk of burning or scalding!

Components may be hot.

Pressurized steam may exist in the system.

Before any service work is performed, allow time to cool.

Refer to Figure 5-51 – Water Path Connection.

1.Remove the retaining spring (Item 1).

2.Pull out the hose from the connector.

3.Remove the sealing rings (Item 2).

1Retaining Spring

2Sealing Rings

3Pressed-on Ring

Figure 5-51:Water Path Connection

5.46Water Path Connections - Closing

1.Check the sealing rings for damage and replace as necessary.

2.Fit the sealing rings on the hose.

3.Insert the hose in the connector.

4.Fit the retaining spring behind the pressed-on ring.

5.As a check, pull on the hose. It should not be possible to pull the hose out of the connector.

97

Page 97
Image 97