Refer to Figure 5-24.

CVA615 Coffee System

Technical Information

5.27Brew Unit – Manual Reset to “Home Position” (with Brew Unit Not Installed in Appliance)

Refer to Figure 5-24.

1.Press on the latch A; and press the funnel down B.

2.Push the connection piece to the far left position C.

3.Press "PRESS" once.

Figure 5-24:Moving the Brew Unit to “Home Position”

4.The “Home” position (Figure 5-25) after resetting the Brew Unit. The Brew Unit can now be installed into the appliance.

Figure 5-25:Brew Unit in Reset Position