Miele CVA615 manual 5.32Brew Unit Drives - Service

Models: CVA615

1 104
Download 104 pages 36.29 Kb
Page 77
Image 77
5.32Brew Unit Drives - Service

CVA615 Coffee System

Technical Information

5.32Brew Unit Drives - Service

1.Disconnect the power. Allow the appliance to cool.

2.Remove the Brew Unit from the appliance – Refer to Section 5.20.

3.Remove the Waste Container from the appliance.

4.Remove the Beans Container and Beans Container Guide – Refer to Section 5.36 and 5.37.

5.Remove the lid – Refer to Section 5.1.

6.Remove the Rear Panel – Refer to Section 5.2.

Important!

Before unplugging any connections, label the plugs and connectors to ensure the wiring is returned to the correct locations during reassembly.

7.Disconnect L1 and N from the Door Switch to the Interference Suppressor

8.Disconnect the ground wires from the Cord Socket / Terminal Block.

9.Disconnect the following connections from the Power Electronic:

ƒJP2

ƒJP12

ƒJP4

10.Disconnect the following connections from the CPU Electronic:

ƒJP34

ƒJP35

ƒJP25

ƒJP39

ƒJP41 (Ribbon Cable)

11.Disconnect the ground connection from the Dispenser Solenoid.

12.Disconnect the ground connection from the Hot Water Heater.

13.Remove the CPU Electronic (with its mounting assembly) and position toward the rear outside of the appliance.

14.Remove the Steam Heater from its mount and position it outside the appliance.

15.Disconnect the Water Intake Connection to the Hot Water / Coffee Heater

77