Miele CVA615 manual 5.19Checking Temperature at Coffee Dispenser

Models: CVA615

1 104
Download 104 pages 36.29 Kb
Page 63
Image 63
5.19Checking Temperature at Coffee Dispenser

CVA615 Coffee System

Technical Information

5.19Checking Temperature at Coffee Dispenser

Warning!

To avoid adverse operating conditions:

ƒDo not deviate from the procedure.

ƒDo not change any other settings or values during this procedure.

1.Set the grinding grade to medium.

2.Set the coffee quantity to medium.

3.Set the Medium Coffee temperature to medium (standard setting).

4.Turn off the appliance.

5.Press and hold the Small Coffee Button, Large Coffee Button and the Hot Water Button. Turn the Selector Switch to the “On with Light” position.

The following is displayed:

LANGUAGE

RINSING

6.Press the Medium Coffee Button 12 times. The following is displayed:

DIAGNOSIS

LANGUAGE

7.Press the Small Coffee Button 1 time.

8.Press the Medium Coffee Button 2 times.

The following is displayed:

Note:

 

This value may vary

1 COFFEE

N0IMPULS.350

9.Observe the numeric value in the lower right corner of the display.

ƒIf a value of “350” is displayed; proceed to step 14.

ƒIf the value is not 350; proceed to step 10.

10.Press the Small Coffee Button 1 time. A blinking box will appear at the end of the numeric value.