Miele CVA615 manual Release all three coffee buttons

Models: CVA615

1 104
Download 104 pages 36.29 Kb
Page 95
Image 95
4.Release all three coffee buttons.

CVA615 Coffee System

Technical Information

Figure 5-49:Test Jumper Position

4.Release all three coffee buttons.

5.Remove the jumper and reconnect JP25.

6.Press and hold all three coffee buttons. Observe the number displayed in the bottom right of display (refer to Figure 5-50).

Figure 5-50:Display While in Service Mode

Is the displayed value 30 or higher?

NO

YES

Normal operation

Ensure…

ƒSufficient water is present

ƒThe water path is clear

ƒWater lines are not crimped

ƒHeaters, flowmeter, etc. freely pass water

ƒWater valves fully open

ƒWater line connections are tight & do not leak

95

Page 95
Image 95
Miele CVA615 manual Release all three coffee buttons