3.SETUP

3.SETUP

AC Power

Fuse

Replacement

The Intimidator™ Wash Zoom 250 IRC has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz.

To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the values listed on the label affixed to the product’s back panel, or refer to the product’s Specifications. The listed current rating indicates the product’s average current draw under normal conditions.

The Intimidator™ Wash Zoom 250 IRC can be power linked via the IEC and Edison outlets in its base.

Always connect the product to a protected circuit (circuit breaker or fuse). Make sure circuit has an appropriate electrical ground to avoid the risk of electrocution or fire.

Never connect the product to a rheostat (variable resistor) or dimmer, even if the rheostat or dimmer serves only as a 0 to 100% switch.

1.Make sure product is not connected to a power source.

2.Place the tip of a flat-head screwdriver into the slot in the fuse holder.

3.Turn the screwdriver counterclockwise and the fuse holder will come loose.

4.Pull the fuse holder out of the product.

5.Pull the blown fuse out of the fuse holder.

6.Place a new fuse of the exact same type and rating into the fuse holder.

7.Insert the fuse holder into the product.

8.Place the tip of a flat-head screwdriver into the slot in the fuse holder.

9.Turn the screwdriver clockwise and the fuse holder will tighten into place.

Disconnect the product from power before replacing the fuse.

Use only the fuse listed in the Technical Specifications section or on the specifications sticker on the product.

A spare fuse is not included.

Page 8 of 29

Intimidator™ Wash Zoom 250 IRC User Manual Rev. 1

Page 8
Image 8