DMX Primer
There are 512 channels in a DMX connection. A fixture capable of receiving DMX will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation. In other words, the fixtures will all respond exactly the same.
DMX fixtures are designed to receive data through a daisy chain. A daisy chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair DMX data cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative
Fixture Linking (Daisy Chain)
You will need a daisy chain to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a daisy chain determines the number of fixtures the data link can support.
To comply with the
Maximum recommended cable distance: 500 m (1640 ft)
Maximum recommended number of fixtures on a daisy chain: 32
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET® certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use
DMX Data Cable
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA
Type: | shielded, | |
Maximum capacitance between conductors: |
| 30 pF/ft |
Maximum capacitance between conductor and shield: | 55 pF/ft | |
Maximum resistance: |
| 20 ohms/1000 ft |
Nominal impedance: |
| 100 ~ 140 ohms |