Chauvet Indoor Furnishings Setting up a DMX Serial Data Link, C Able Connectors, Dmx +, Input

Models: Indoor Furnishings

1 18
Download 18 pages 40.09 Kb
Page 9
Image 9
C ABLE CONNECTORS

C ABLE CONNECTORS

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.

DMX connector configuration

 

 

COMMON

 

1

DMX +

INPUT

3

 

 

2

DMX -

 

 

1

Resistance 120

ohm 1/4w between

3

pin 2

(DMX -) and

2

pin 3

(DMX +) of

the last fixture.

1

OUTPUT

3

2

Termination reduces signal errors. To

avoid signal transmission problems

 

 

and interference, it is always

 

advisable to connect a DMX signal

 

terminator.

CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.

3- PIN TO 5 - PIN CONVERSION CH ART

Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. CHAUVET Model No: DMX5M, or DMX5F.

The chart below details a proper cable conversion:

3PIN TO 5 PIN CONVERSION CHART

Conductor

3 Pin Female (output)

5 Pin Male (Input)

 

 

 

Ground/Shield

Pin 1

Pin 1

 

 

 

Data ( - ) signal

Pin 2

Pin 2

Data ( + ) signal

Pin 3

Pin 3

Do not use

 

Pin 4

Do not use

 

Pin 5

Setting up a DMX Serial Data Link

Universal DMX Controller

 

1. Connect the (male) 3 pin connector side of

 

the DMX cable to the output (female) 3 pin

 

connector of the controller.

 

2.Connect the end of the cable coming from the controller which will have a (female) 3

pin connector to the input connector of the

This drawing provides a

next fixture consisting of a (male) 3 pin

general illustration of the

connector.

DMX Input/Output panel of

 

a lighting fixture.

3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.

CHAUVET Certified DMX Data Cables

Order Code

Description

DMX1.5

DMX Cable 1.5m/4.9ft

Continue the link

COLORstrip™ Mini User Manual

9

1/26/2010 2:49 PM

Page 9
Image 9
Chauvet Indoor Furnishings Setting up a DMX Serial Data Link, C Able Connectors, PIN TO 5 - PIN CONVERSION CH ART, Dmx +