e.Replace the Transmission Box Cover (2F), and secure it with the Screws (1F).

(See Figure C.)

V-BELT

(3F)HEX BOLT

(11F)

SCREW

(1F)

BOLT

(14F)

HEX BOLT

TRANSMISSION BOX COVER(11F) (2F)

TENSIONING NUT

FIGURE C

(35F)

4.To clean the Pre-Filter 1 (2E), Pre-Filter 2 (3E), Filter Housing (4E), Paper Air Filter (5E), and Secondary Filter (6E): It is recommended to clean the Pre-Filter 1, Pre-Filter 2, Filter Housing, Paper Air Filter, and Secondary Filter every 48 hours of use. To do so, pull the Filter Cover Lock Lever (13E) backward to allow the Air Filter Cover (1E) swing open. Remove the Pre-Filter 1, Pre Filter 2, Filter Housing, and Paper Air Filter in succession. Clean and dry the parts or replace if necessary. Once cleaned or replaced, install the parts in reverse order of removal and close the Air Filter Cover. (See Figure D.)

AIR COVER

 

 

 

 

LOCK LEVER

SECONDARY

FILTER HOUSING

(13E)

FILTER

(4E)

 

 

 

 

(6E)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAPER AIR

PRE-FILTER 1

AIR FILTER COVER

FILTER

(2E)

(1E)

(5E)

PRE-FILTER 2

 

 

 

 

FIGURE D

 

 

(3E)

 

 

 

 

5.To service the Spark Plug (2B): If the Engine loses power, is difficult to start, or runs poorly at idling speed, first check the condition of the Spark Plug. To check the Spark Plug:

a.Remove the Spark Plug Cover (4D) located at the front of the Rear Handle (7D).

(See Figure E.)