RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOLT)

NAMEPLATE

 

EXTENSION CORD LENGTH

 

AMPERES

 

 

 

 

 

 

 

(at full load)

 

 

 

 

 

25 Feet

50 Feet

75 Feet

100 Feet

150 Feet

 

 

0 – 2.0

18

18

18

18

16

2.1

– 3.4

18

18

18

16

14

3.5

– 5.0

18

18

16

14

12

5.1

– 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1

– 16.0

14

12

10

-

-

16.1

– 20.0

12

10

-

-

-

TABLE A * Based on limiting the line voltage drop to five volts at 150% of the rated amperes.