Grounding

WARNING!

!

The GFCI cannot protect you against any potential difference that exists between the nutrunner body and any other metal fixturing or machinery. You must observe the grounding requirements below as a safety protection. Failure to follow this safety guideline can result in serious personal injury.

It is extremely important that you connect the CS7000 Controller enclosure properly to an earth ground. The CS7000 Controller has a ground prong on the power cord, (if supplied) but the AC outlet that will be used must be grounded properly, as well.

Also make sure that all other machinery, such as conveyors, which will transport or hold parts that will come in physical contact with the nutrunner, are properly grounded.

I/O Wiring

The CS7000 Controller is equipped with a 19-pin I/O connector for field I/O. The settings described in Table 3-1 are VS default settings. The CS7000 Controller is capable of 12 discrete inputs and 12 discrete outputs, however, the standard 19-pin I/O connector does not accommodate I/O 9 through 12. These extended I/O must be wired to the backplane directly if they are required. DCMII revision 3.00 or higher also supports 128 parameter sets and 16 sequences.

NOTE:

The 14-shell, 19-pin strain relief mating connector for the I/O

?

connector is part number 23-10-5200 [PT06A-14-19P (SR)].

 

Table 3-1. 19-Position Remote I/O Connector Pinout Signal Names and Descriptions

Pin

Signal

Description

 

 

 

A

Cycle On/Cycle On Enable

This is a dual-purpose input.

 

Clear Outputs

When Set Defaults is clicked, VS sets this input to Start, this input

 

(Black wire - internal)

 

functions as a cycle on input. This means a fastening cycle can be

 

(Black wire - external)

 

started by either pressing the throttle/trigger switch on the nutrunner OR

 

 

 

 

by activating this input.

 

 

When remote mode for the spindle is set to enable, this input functions as

 

 

a cycle on enable input. This means a fastening cycle can be started only

 

 

by pressing both the throttle/trigger switch on the nutrunner and activating

 

 

this input.

 

 

In addition, it is also set to Clear Outputs.

 

 

This is a level-sensitive input. For the fastening cycle to proceed, this

 

 

input must remain active. If this input becomes inactive at any time during

 

 

the fastening cycle, the cycle will be aborted and the nutrunner will stop

 

 

running.

 

 

 

Page 3-4