INSTALLATION INSTRUCTIONS
EVCM-100D
Magna Lift™ Electric Ceiling Mount
Prior to assembly, unpack carton completely and verify contents.
If you are missing any of the following components, please contact Customer Service at
BEFORE PROCEEDING, READ INSTALLATION INSTRUCTIONS COMPLETELY
WARNING! IMPROPER INSATLLATION MAY RESULT IN SERIOUS PERSONAL INJURY! All components must be securely fastened to each other and to the ceiling. The overhead support must be capable of supporting five times the weight of the mount and equipment combined. If it cannot is MUST be reinforced.
Unit Specifications
Motor Operation Limits
Run Time - 12 Minutes*
Cool Time - 25 Minutes
Run Time - 12 Minutes
Do not exceed two cycles without an extended cooling period of 45 minutes. To prevent damage to the Magna Lift, the unit will shut down for cooling if overheated.
* It will take approximately 11 minutes to fully lower and raise 20 feet of cable under maximum load.
Maximum Weight Capacity | 250 lbs. (113.5) |
Maximum Travel | 20 feet (609.6 cm) |
Unit Weight | 48 lbs. (21.6 kg) |
Electrical Requirements | 115 volts, 60 Hz, 1.6 amps continuous |
Read instructions completely before installing unit and connecting power.
1.Ensure
2.Ensure support for the
3.Use the optional
AThread the unit on the NPT 1 1/2" column and tighten securely using pipe wrench.
BAfter unit is tightened securely, install the thread locking set screw [Figure 1, Item (1) into the coupler, tightening it against threads on column.
CHIEF MANUFACTURING INC.
Page 1 of 3 |