STRUT CHANNEL REQUIREMENTS (LVSXU)
IMPORTANT ! : Strut channel must be made of steel with a minimum yield strength of 33ksi (230MPa), and meeting the profile and dimension requirements outlined.
Table 1: Strut Channel Dimension Requirements
STEEL THICKNESS | DIMENSION (See Figure 2) |
|
|
14 ga [0.075"] (2.5mm) | K = 13/16" (21mm) |
12 ga [0.104"] (3mm) |
|
13/16" (21mm) < K < | |
14 ga or 12 ga |
|
L (minimum) = 1/4" (6mm) | |
| L (maximum) = 9/32" (7mm) |
|
|
Strut Channel Profile
(41mm)
3/8"
7/8" (10mm) (22mm)
L
K
IMPORTANT! All dimensions other than "L" and "K" are nominal requirements.
UNACCEPTABLE strut channel profiles
Strut channel MUST have | Strut channel MUST NOT |
rolled up lips on both sides | have holes or slots on |
of channel. | side walls of channel. |
Figure 3
Figure 2
MOUNTING PATTERN OFFSET CALCULATION
Center line of display
Center line of mounting pattern
Mounting pattern of display
Offset (H)
NOTE: An offset measurement (H) is required if the centerline of the display does not match the centerline of the display mounting pattern.
1.If display mounting pattern is BELOW display centerline:
2.If display mounting pattern is ABOVE display centerline:
Figure 4