PLP INSTALLATION (Cont’d)

Installation Instructions

PLP Series

PLP INSTALLATION (Cont’d)

Mount the PLP

To mount the PLP, do the following:

1.Holding the PLP against the wall, select the pair of mounting holes that best suits your situation (see Figures 5, 6, and 7).

NOTE: The mounting holes are slotted to allow for a small degree of lateral movement. The mount can be centered, or shifted to the left of center, or right of center depending on stud location.

2.Depending on your situation, install the lag bolts and washers into the pilot holes previously drilled, as described below.

￿ Option A. Install four 5/16” x 2-½” lag bolts (20) and four 5/16” washers (30) (two top and two bottom) into the mounting holes, centering the PLP on dual wood studs 16” apart on center as shown in Figure 5.

OR

￿Option B. Install four 5/16” x 2-½” lag bolts (20) and four 5/16” washers (30) (two top and two bottom) into the mounting holes that are right of center on dual wood studs 16” apart as shown in Figure 6.

OR

￿Option C. Install four 5/16” x 2-½” lag bolts (20) and four 5/16” washers (30) (two top and two bottom) into the mounting holes that are left of center on dual wood studs 16” apart dual wood studs 16” apart on center as shown in Figure 6.

OR

￿ Option D. Install four 5/16” x 2-½” lag bolts (20) and four 5/16” washers (30) (two top and two bottom) into the mounting holes, centering the PLP on dual wood studs 24” apart on center as shown in Figure 7.

3.Tighten all lag bolts.

Option A

Figure 5. Mounting Holes – 16” Apart on Center

(Option A)

Option B

Option C

Figure 6. Mounting Holes – 16" Apart on Center

(Options B and C)

Option D

Figure 7. Mounting Holes – 24" Apart On Center

(Option D)