Removing and Replacing a Card Cage Assembly
Removing a DC-Input Power Supply
Perform the following steps to remove a
Caution Before performing any of the following procedure, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.
Step 1 Attach an antistatic wrist strap to yourself and to one of the two ESD connection sockets located on the front edges of the upper card cage or to bare metal on the frame.
Step 2 If you have not already done so, turn OFF (O) the power switch on the
Warning Voltages might be present on the
Note Turning the power supply switch to OFF (O) releases a latch that secures the power supply in the power supply bay.
Step 3 Locate and turn off the source DC circuit breaker that services the power supply you want to remove. As an added precaution, tape the circuit breaker handle in the off position.
Step 4 Using a
Step 5 Grasp the power supply handle and slide the power supply halfway out of the bay. (Refer to Figure 4.)
10Cisco 12012 Gigabit Switch Router Card Cage Assembly Replacement Instructions