Removing and Replacing a Card Cage Assembly

Removing the System Grounding

Your system might have two system grounding cable lugs attached to two system receptacles located on the card cage assembly side flanges between the air filter tray and the power supply bays. (Refer to Figure 12.) You must remove the system grounding connector before you can remove card cage assembly.

Figure 12 System Grounding Receptacles

H10899

System grounding

receptacles

Perform the following steps to remove a system grounding lug from the card cage assembly:

Step 1 Remove the two screws, washers, and nuts that secure the system grounding lug to the card cage assembly. (Refer to Figure 13.) Save the mounting hardware, you will use it in a later procedure.

Step 2 Remove the system grounding cable and set it aside.

Repeat Step 1 and Step 2 for a second system grounding connector.