Chapter 2 Camera Installation

IP Camera Installation

The GPIO terminal block pin locations and descriptions are as follows:

1 2 3 4 5 6 7 8

Pin

Description

1

12 VDC-

 

 

2

12 VDC+

 

 

3

24 VAC

 

 

4

24 VAC

 

 

5

DI-

 

 

6

DI+

 

 

7

DO-

 

 

8

DO+

 

 

Step 6 (Optional) Use a mini cable with BNC connector to temporarily attach an NTSC or PAL compliant analog video display device to the analog video out port on the IP camera.

Note The mini cable with BNC adapter is included in the audio/video cables accessory kit, which you can purchase from Cisco (Cisco part number CIVS-AVCABLE).

Analog video is enabled by default to allow you to adjust the camera field of view during installation. However, it is not supported as a normal camera feed and is automatically disabled when any of the following camera settings are made:

The primary video stream frame rate must be set higher than 15 fps.

The secondary video stream must is enabled.

Note We recommend that you disable analog video after installation. To disable analog video, see the Cisco Video Surveillance 6000 Series IP Camera Configuration Guide.

Step 7 Remove the black cover.

Step 8 While viewing video from the IP camera, perform the following steps to adjust the 3-axis field of view:

a.Grip the two tilt adjustment screws and pan the IP camera left or right.

b.Loosen the two thumb screws, tilt the IP camera, then tighten the thumb screws.

c.Rotate the IP camera to adjust the image horizontal orientation.

Cisco Video Surveillance 6020 IP Camera Installation Guide

 

OL-28120-02

2-5

 

 

 

Page 17
Image 17
Cisco Systems 6020 IP manual 3 4 5 6 7