Chapter3 Installing the Chassis
Connecting Power
3-12
Cisco Metro 1500 Series Hardware Installation Guide
78-10588-03

Figure3-5 Rear Panel of the PSM (US Version)

Caution Donot use damaged terminal blocks. Immediately replace damaged

or defective terminal blocks

Step 3 Take a medium screwdriver and push it into the rectangular hole of the terminal

block.(See Figure 3-6.)At the same time, slide the insulation-free end of the wireintothe respective rectangular hole at the bottom of the power clamp. Repeat thisstep for the other wires.

Instructions for

power supply

Fan module

Fuse 2 Fuse 1
March 1999
For continued protection against risk of fire replace
only with same type and ratings of fuse.
For proper selection of power supply cord refer to
instruction manual.
Always remove both poewr cords whendisconnecting from a power source.Voltage: Power ConsumptionFuse: 2 115/230 V 50/60 HzMax. Current: 2.5 A max. 100 Wx T 2,5 A / 250 V
Made in Germany
Always remove both
power cords when dis-
connecting from power
source !
!

Terminal blocks Fuse

holders

Power 2 Power 1
50327