Warning The illustration shows the DC power supply terminal block. Wire the DC power supply using the appropriate wire terminations at the wiring end, as illustrated. The proper wiring sequence is ground to ground, positive to positive, and negative to negative. Note that the ground wire should always be connected first and disconnected last.
Caution In a DC power supply installation do not connect the
Step 2 Strip off a quarter of an inch (1/4 in. [0.625 cm]) of insulation on the safety ground, +48 VDC, and
Step 3 Install the safety ground (green wire) into the terminal block ground connector and tighten the locking screw. Ensure that no bare wire is exposed.
Caution Do not overtorque the terminal block contact screws. The recommended torque is 8.2 ± 0.4
Step 4 Insert the +48 VDC wire into the terminal block positive connector (+) and tighten the locking screw. Ensure that no bare wire is exposed.
Step 5 Insert the
Step 6 Secure the power supply cord to the cable
Warning After wiring the DC power supply, remove the tape from the circuit breaker switch handle and reinstate power by moving the handle of the circuit breaker to the ON position.
Mounting screw | Mounting screw | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Terminal |
block |
Mounting screw
clamp
On/off switch
H10720
Power Up the Cisco AS5300
Power up the access server. The internal power supply fan should power on. Messages will begin to appear on your console screen.
Caution After you start the Cisco AS5300, it might take several minutes for the startup messages to stop. Do not press any keys until you see the following message:
Would you like to enter the initial configuration dialog? [yes]:
While you are waiting for this message to appear, proceed to Section 3 Gather Configuration Information.